BSEN60893-3-4-PFGC201 B30 Phenolic Glass Laminate SRBG

Material Details

Grade:B30
Description: Phenolic Glass. High temperature low smoke emission
Comments:The high quality resin systems used impart good electrical insulation and high mechanical strength, low water absorption and good thermal shock resistance. Suitable for general purpose use at Class F temperatures and above. Low smoke emission / low toxicity. LUL Approved (SE970).
Specifications:BSEN60893-3-4-PFGC201 (Which supersedes BS3953 PF2). The closest NEMA equivalent to this specification is NEMA G3
Body Colour:Dark Brown
Cover Colour:Dark Brown
Finish:Matt
Size:1220 x 1220
Thickness Range: 0.4 - 100.0

Typical Applications

  • Chemical Resistance Components
  • Electromechanical Machining Jigs
  • High Temperature Components
  • High Voltage Insulation
  • Low Voltage Insulation
  • Slot Wedges
  • Terminal Boards and Tag Strips
  • Thermal Splash Barriers
  • Welding Jigs

General Properties

Property Unit of measure Typical Value
Densityg/cm31.9
Water Absorptionmg56
Flammability Category¥--FV0
¥ Where relevant, the flammability test method is used solely to control and monitor consistency of production. Under no conditions should the results be considered in relation to fire hazards under actual conditions of use.

Electrical Properties

Property Unit of measure Typical Value
IR (24hrs Water Immersed)G Ω7.6
IR (Dry)G Ω7.6
Electric Strength (Flat Rapid)MV/m8.1
Breakdown Voltage (Edge Step by Step)kV44
Tracking IndexV110

Mechanical Properties

Property Unit of measure Typical Value
Flexural StrengthMPa360
Tensile StrengthMPa200
Impact (Notched CHARPY)kJ/m252

Thermal Properties

Property Unit of measure Typical Value
Thermal Rating Continuous°C155
Thermal Rating Intermittent°C200

Disclaimer: The above values are based upon routine test data and do not form the basis of a supply contract. These products may be used in a diverse range of applications and whilst every effort is made to ensure the information in this data sheet is accurate, it must be stressed that it is the user’s responsibility to ensure suitability for the intended end use.